Beaufort Aluminium Slimline Bi-fold Doors Technical Page

View/Download  Beaufort Sections and Thresholds Identification
View/Download  Beaufort Thresholds, Floor Levels, Drainage

Beaufort Bi-fold Quality Control

All of our Bi-folding doors are fully assembled and tested in the factory jigs prior to despatch.

They are photographed up to 28 times to ensure they reach you in perfect working condition.

These photographs are then put into every accessory box that is sent out with every door along with full fitting instructions.

Note: The above would not apply if we are fitting for you, as our experienced fitters know exactly what they are doing.

We believe that the best way to make sure that every single one of our Bi-fold doors arrives to you in an excellent working condition, is to check them thoroughly before they leave the factory. Each Bi-fold door therefore that leaves the factory is checked by Quality Control; for more details see our Quality Control page.

Please note that the statistics below apply when using: Double-glazing, argon filled (low-E, en=0.05, soft coat), 16mm or more (1.2 Glass - U Value centre Pane*).

Beaufort Bi-folding Doors Specifying - Suitable Applications

  • Can be specified for residential / domestic applications.
  • Meets building regulations for new build. (For Oct 2010)
  • Meets building regulations for replacement and refurbishment projects. (For Oct 2010)
  • Standard fully weather rated threshold; suitable for use up to second floor and exposed locations.
  • Flush low threshold options; suitable for use on the ground floor only, not recommended for use in exposed locations or properties situated by the coast.

Beaufort performance

1.7
U Value
W/M²K
600 Pa
Air
Permeable
750 Pa
Water
Tightness
1800 Pa
Wind
Resistance

These statistics apply for: Open out doors, double-glazed units, 90% argon gas filled (4mm Planitherm total +, 3mm Planilux), 16mm or more, Swiss V warm edge spacerbar (1.2 Glass - U Value centre Pane*).

Beaufort Bi-fold Sizes

Min. Overall Width (mm)1400
Max. Overall Width (mm)6250+
Min. Overall Height (mm)1600
Max. Overall Height (mm)3000
Min. Panel Width (mm)700
Max. Panel width (mm)1200
Max. Weight Per Panel (kg)120

*Please Be Advised: Doors over 2500mm tall maybe subject to a wind loading check. In which case we will need to know the location, postcode and facing of the doors.

Beaufort Bi-fold Door Frame Dimensions

Outer frame depth at the edge - front to back(mm) 70
Sash Depth - front to back (mm)70
Threshold Height (mm) Standard54 (step=35)
Low Thresholds Height (mm)34 (step=15)
Room Divider Threshold Height (mm) 22 (step=3)
Glass - Clear Toughened (mm)28 ( 4 x 20 x 4)

Beaufort Bi-folds Glass Sight-lines

Head (mm)110
Bottom (Including Room divider threshold) (mm)118
Bottom (Including threshold) (mm)130
Bottom (Including Threshold & drip tray)(mm)151
Jambs (mm)110
Meeting Stiles (mm)140

Beaufort Bi-fold Number of Door Panels

No of Door Panels 2 3 4 5 6 7 8+
Minimum Width (mm) 1400 2100 2800 3500 4200 4900 Please ask
Maximum Width (mm) 2000 3000 4000 5000 6000 7000 Please ask


Please remember all sizes are for guidance only and are subject to location of the fitted product. Please contact us for more information.

Beaufort Bi-fold Threshold Options

54mm Standard Rebated Threshold (CA)

Open Out Doors
Standard Threshold
(Fully Weather Rated)
Open In Doors
Standard Threshold
(Fully Weather Rated)
Open Out Doors
Standard Threshold + Cil
(Fully Weather Rated)
Open In Doors
Standard Threshold + Cill
(Fully Weather Rated)

34mm Flush Low Threshold (CB)

Open Out Doors
Low Threshold
(Recommended For Use In Low - Medium Exposed Areas)
Open In Doors
Low Threshold
(Recommended For Use In Low - Medium Exposed Areas)
Open Out Doors
Low Threshold + Cil
(Recommended For Use In Low - Medium Exposed Areas)
Open In Doors
Low Threshold + Cill
(Recommended For Use In Low - Medium Exposed Areas)

34mm Ramped Flush Low Threshold (CC)

Open Out Doors
Ramped Low Threshold
(Recommended For Use In Low - Medium Exposed Areas)
Open In Doors
Ramped Low Threshold
(Recommended For Use In Low - Medium Exposed Areas)

22mm Flush Low Non-Thermal Threshold (CD)

Open Out Doors
Room Divider Threshold
(For Interior Use Only)
Open In Doors
Room Divider Threshold
(For Interior Use Only)